Disclaimer: The app acts as a configuration and command tool for compatible fire and security panels installed at customer premises. These panels accept only SMS commands in predefined formats. The app sends these SMS commands directly to the panel’s SIM card number to:
- Add or update user contact numbers stored in the panel memory.
- Add or update panel address or signature.
- Reset or trigger specific panel outputs such as sounder OFF, evacuation trigger, or panel reset.
- Delete previously stored contacts or signatures.
All SMS messages follow strict, predefined formats required by the panel firmware
For Neuron Panels:
Add Panel Process:
Case Number 01: To Add/Update 10 User numbers to the Panel:
(the APP will send 2 SMSs for add 5 number from 1st SMS and next 5 number from 2nd SMS):
SMS 1:
< 1234 TEL NO
# 01 – 9876543210 *
# 02 – 1234567890 *
# 03 – 1234567890 *
# 04 – 1234567890 *
# 05 – 1234567890 *
>
SMS 2:
< 1234 TEL NO
# 06 – 9876543210 *
# 07 – 1234567890 *
# 08 – 1234567890 *
# 09 – 1234567890 *
# 10 – 1234567890 *
>
Response from Panel:
ACK : TEL NO ADDED / EDITED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
Case Number 02: To Add address to the Panel:
SMS: < 1234 SIGNATURE #_______* >
(in ______, user will able to attach Signture to the Panel)
Response from Panel:
ACK : GSM SIGNATURE UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
NOW ADDING PANEL PROCESS IS COMPLETE, now IF user want to update User Mobile Numbers and/or update SIGNATURE, User have to send above message with updated inputs!
Commanding Panel Process:
Case No 1: To RESET the Panel:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 02 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 02 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
Case No 2: To TURN the SOUNDER OFF:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 03 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 03 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
Case No 3: To TRIGGER the EVACUATION:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 04 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 04 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
DELETE Panel Process:
Case Number 01: To Delete 10 User numbers to the Panel:
(the APP will send 2 SMSs for add 5 number from 1st SMS and next 5 number from 2nd SMS):
SMS 1:
< 1234 TEL NO
# 01 – 0000000000 *
# 02 – 0000000000 *
# 03 – 0000000000 *
# 04 – 0000000000 *
# 05 – 0000000000 *
>
SMS 2:
< 1234 TEL NO
# 06 – 0000000000 *
# 07 – 0000000000 *
# 08 – 0000000000 *
# 09 – 0000000000 *
# 10 – 0000000000 *
>
Case Number 02: To Add address to the Panel:
SMS: < 1234 SIGNATURE #_______* >
(in ______, user will able to attach Signature to the Panel)
NOW DELETE PANEL PROCESS IS COMPLETE, now User can’t command to the Panel from now and also Panel will not Send any message to the Last Numbers!
For 4G Com Panels:
Add Panel Process:
Case Number 01: To Add/Update 1 Admin Number to the Panel:
SMS : “SECURICO 1234 ADD ADMIN +91 – 9876543210 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
Case Number 02 : To Add/Update Signature to the Panel
SMS : “SECURICO 1234 ADD SIGNATURE ________ END”
(in ______, user will able to attach Signature to the Panel)
Response from Panel:
SIGNATURE ADDED SUCCESSFULLY
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
[OPTIONAL]
Case Number 03 : User can also Add 10 other numbers also to get the Alert Messages from Panel:
for 1st User number:
SMS : “SECURICO 1234 ADD USER01 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 2nd User number:
SMS : “SECURICO 1234 ADD USER02 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 3rd User number:
SMS : “SECURICO 1234 ADD USER03 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 4th User number:
SMS : “SECURICO 1234 ADD USER04 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 5th User number:
SMS : “SECURICO 1234 ADD USER05 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 6th User number:
SMS : “SECURICO 1234 ADD USER06 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 7th User number:
SMS : “SECURICO 1234 ADD USER07 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 8th User number:
SMS : “SECURICO 1234 ADD USER08 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 9th User number:
SMS : “SECURICO 1234 ADD USER09 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
for 10th User number:
SMS : “SECURICO 1234 ADD USER10 +91 – 1234567890 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER ADDED SUCCESSFULLY
http://www.securicoelectronics.com/
To Update Panel, above messages can be reused to Update Panel data and related data!
Commanding Panel Process:
Case No 1: To RESET the Panel:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 02 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 02 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
Case No 2: To TURN the SOUNDER OFF:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 03 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 03 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
Case No 3: To TRIGGER the EVACUATION:
(we need to SEND 2 SMSs)
SMS 1: < 1234 OUTPUT 04 ON >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
SMS 2: < 1234 OUTPUT 04 OFF >
Response from Panel:
ACK : OUTPUT ONOFF UPDATED
TIME : 00:00
DATE : 00/00/00
SIGNATURE FROM PANEL
DELETE Panel Process:
Case Number 01: To Delete 1 Admin Number to the Panel:
SMS : “SECURICO 1234 ADD ADMIN +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
Case Number 02 : To DELETE Signature to the Panel
SMS : “SECURICO 1234 ADD SIGNATURE ________ END”
Response from Panel:
[OPTIONAL, IF ADDED]
Case Number 03 : User can DELETE 10 other numbers:
for 1st User number:
SMS : “SECURICO 1234 ADD USER01 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 2nd User number:
SMS : “SECURICO 1234 ADD USER02 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 3rd User number:
SMS : “SECURICO 1234 ADD USER03 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 4th User number:
SMS : “SECURICO 1234 ADD USER04 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 5th User number:
SMS : “SECURICO 1234 ADD USER05 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 6th User number:
SMS : “SECURICO 1234 ADD USER06 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 7th User number:
SMS : “SECURICO 1234 ADD USER07 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 8th User number:
SMS : “SECURICO 1234 ADD USER08 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 9th User number:
SMS : “SECURICO 1234 ADD USER09 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY
http://www.securicoelectronics.com/
for 10th User number:
SMS : “SECURICO 1234 ADD USER10 +91 – 0000000000 END”
Response from Panel:
USER UPDATED MSG FROM
SECURICO SECURITY SYSTEM
USER REMOVED SUCCESSFULLY