Venus


4 Zone Control Panel with Onboard Key Pad and inbuilt 2 Message 30 Number Speech Dialer. Inbuilt Power Supply.

SEC - 04V

 

Features:

CONTROL PANEL
  • Micro-controller based
  • 4 zone control panel
  • On board key pad
  • Two fully programmable codes (master and servant codes)
  • 20000 code combinations
  • One delay zone, one immediate zones, one 24 hour panic zone, one 24 hour fire zone
  • Built in battery backup provision
  • Zone omitting facility
  • 9 led display
  • 5 leds indicate operational status
  • 4 leds indicate individual zone status
  • Entry/ exit time 2 to 255 seconds
  • Sounder time 2 to 20 minutes
  • Silent arming
  • Night mode arming
  • Intrusion log
  • Dedicated panic and quick arm keys
  • Power failure indication
  • Blown fuse indication
  • Non-volatile memory
  • 16 key backlit keypad
  • Bell and strobe light outputs
  • Open zone indication
  • Zone status led indicators
  • Automatic rearming after an intrusion
  • Only three incorrect attempts allowed to disarm the system after which the system goes into alarm state
  • Musical audio indication
  • Multiple sounder outputs
  • Elegant white abs body

 

BUILT IN SPEECH DIALER
  • Micro-controller based
  • 2 messages
  • Separate intrusion message
  • Separate fire message
  • 15 telephone numbers for intrusion message
  • 15 telephone numbers for fire message
  • 20 second recording time for each message
  • Operates with both tone & pulse
  • Message playback
  • Telephone number check
  • Non-volatile memory
  • Power status led
  • Dialing status led
  • Silent Dialing
  • Can work on EPABX line
  • Self test on reset
  • Line overriding
  • Sound precision switch
  • Musical audio indication
  • In-built tamper switch

Datasheet

Brochure

.

Technical Specification

ELECTRICAL
Quiescent current 75 mA typical
current with dialing & message play: 160 mA
Maximum sounder 1 current output: 1A
Maximum sounder 2 current output: 1A
Sounder saturation Voltage: < 1V at 1A
Remote keypads: Up to five
Non-volatile Memory: Programming and Log
Zone response time: <500ms
Zone Loop Resistance: <5k ohm for NORMALLY CLOSED
 
POWER SUPPLY
Mains supply Voltage: 220+10%-15% 50Hz
Total current Output: 800mA at 220V AC (Fuse JA 20mm On Main Card)
Regulation: <9%
Ripple: <200mV RMS
Battery Voltage: 12V DC
Battery type: SMF Rechargeable
Battery Recharge Voltage: 13.8V +/-0.2V DC
Fuse: 250ma 20mm AC Mains on PS Card
 
ENVIRONMENTAL
Operating Temperature: 0°C to 45°C
Storage Temperature: -20°C to 60°C
Maximum humidity: 95% non-condensing
Environment residential / commercial / light Industrial
 
PHYSICAL
Dimensions: 236mm x 226mm x 80mm
Max Battery Dimensions: 150mm x 110mm x 64mm

Download